Miniature Basic Pressure Sensors
Offset Compensated
Pressure Sensors
Features
all sensors
• 0 to 1 “H2O to 0 to 30 “H2O Pressure Ranges
• 0.5 % linearity
• Offset Compensated
Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
General Description
The Miniature BASIC series pressure sensors are based upon a proprietary technology to reduce the size of the sene www.allsensors.com
sor and yet maintain a high level of performance. The technology is currently being patented. Output offset errors
due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all
significantly reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
These offset compensated sensors give an accurate and stable output over a wide temperature range. This series is
f 408 225 2079
intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +6V
is acceptable.
Physical Dimensions
Input Resittance
1.66 k ohm
Output Resistance
1.66 k ohm
TCR
2600 ppm/°C
TCS
-2200 ppm/°C.
Approvals
MKT
As Is
DATE
With Change
MFG
As Is
All Sensors
DATE
With Change
ENG
As Is
DS-0105 Rev B
DATE
With Change
QA
As Is
DATE
With Change
a 16035 Vineyard Blvd. Morgan Hill, CA 95037
p 408 225 4314
Equivalent Circuit
Pressure Sensor Characteristics Maximum Ratings
Environmental Specifications
Supply Supply Voltage VS
6 Vdc
Temperature Ranges
Common-mode pressure
5 psig
Compensated
Lead Temperature
(soldering 2-4 sec.)
250°C
Operating
-25 to 85° C
Storage
-40 to 125° C
Humidity Limits
0 to 95% RH
0 to 70° C
(non condensing)
Standard Pressure Ranges
Single in Line Packages-SIP
One Port
Two Ports Same Side
Two Ports Opposite Side
Operating Pressure
Part Number
Part Number
1 INCH-G-BASIC
0 - 1 “H2O
1 INCH-D1-BASIC
1 INCH-D2-BASIC
5 INCH-G-BASIC
0 - 5 “H2O
5 INCH-D1-BASIC
5 INCH-D2-BASIC
10 INCH-G-BASIC
0 - 10 “H2O
10 INCH-D1-BASIC
10 INCH-D2-BASIC
20 INCH-G-BASIC
0 - 20 “H2O
20 INCH-D1-BASIC
20 INCH-D2-BASIC
30 INCH-G-BASIC
0 - 30 “H2O
30 INCH-D1-BASIC
30 INCH-D2-BASIC
Part Number
Performance Characteristics for 1 INCH-x-BASIC
Minimum
Nominal
Maximum
Units
--
1.0
--
“H2O
4.0
7.0
14.0
mV
Offset Voltage @ zero differential pressure
--
--
±10
mV
Offset Temperature Shift (0°C-70°C), note 2
--
±0.1
--
mV
Offset Warm-up Shift, note 3
--
±10
--
uV
Offset Position Sensitivity (1g)
--
±15
--
uV
Offset Long Term Drift (one year)
--
±80
--
uV
Linearity, hysteresis error, note 4
--
0.1
±0.5
%fs
Minimum
Nominal
Maximum
Units
Operating Range, differential pressure
--
5.0
--
“H2O
Output Span, @ 5 “H2O, note 5
15
22.5
30
mV
Offset Voltage @ zero differential pressure
--
--
±10
mV
Offset Temperature Shift (0°C-70°C), note 2
--
±0.1
--
mV
Offset Warm-up Shift, note 3
--
±10
--
uV
Offset Position Sensitivity (1g)
--
±15
--
uV
Offset Long Term Drift (one year)
--
±80
--
uV
Linearity, hysteresis error, note 4
--
0.1
±0.5
%fs
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 1 “H2O, note 5
Performance Characteristics for 5 INCH-x-BASIC
Parameter, note 1
Miniature Basic Pressure Sensors
Operating Range, differential pressure
--
10.0
--
“H2O
Output Span, @ 10 “H2O, note 5
15
30
45
mV
Offset Voltage @ zero differential pressure
--
--
±10
mV
Offset Temperature Shift (0°C-70°C), note 2
--
±0.1
--
mV
Offset Warm-up Shift, note 3
--
±10
--
uV
Offset Position Sensitivity (1g)
--
±10
---
uV
Offset Long Term Drift (one year)
--
±80
--
uV
Linearity, hysteresis error, note 4
--
0.1
±0.5
%fs
Minimum
Nominal
Maximum
Units
Operating Range, differential pressure
--
20.0
--
“H2O
Output Span, @ 20 “H2O, note 5
15
30
45
mV
Offset Voltage @ zero differential pressure
--
--
±10
mV
Offset Temperature Shift (0°C-70°C), note 2
--
±0.1
--
mV
Offset Warm-up Shift, note 3
--
±10
--
uV
Offset Position Sensitivity (1g)
--
±5
--
uV
Offset Long Term Drift (one year)
--
±80
--
uV
Linearity, hysteresis error, note 4
--
0.1
±0.5
%fs
Minimum
Nominal
Maximum
Units
Operating Range, differential pressure
--
30.0
--
“H2O
Output Span, @ 30 “H2O, note 5
15
30
45
mV
Offset Voltage @ zero differential pressure
--
--
±10
mV
Offset Temperature Shift (0°C-70°C), note 2
--
±0.1
--
mV
Offset Warm-up Shift, note 3
--
±10
---
uV
Offset Position Sensitivity (1g)
--
±5
---
uV
Offset Long Term Drift (one year)
--
±80
--
uV
Linearity, hysteresis error, note 4
--
0.05
±0.5
%fs
Performance Characteristics for 20 INCH-x-BASIC
Parameter, note 1
Performance Characteristics for 30 INCH-x-BASIC
Parameter, note 1
Specification Notes
note 1: All parameters are measured at 4.5 volt excitation, for the nominal full scale pressure and room temperature unless
otherwise specified. Pressure measurements are with negative pressure applied to the TOP-PORT (the only port for the
single port) configuration.
note 2: Shift is relative to 25°C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure.
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of
any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
All Sensors
DS-0105 Rev B
e www.allsensors.com
Units
f 408 225 2079
Maximum
p 408 225 4314
Nominal
a 16035 Vineyard Blvd. Morgan Hill, CA 95037
Minimum
Parameter, note 1
all sensors